C R O S S A U T O M A T I O N . . . . A P P L I C A T I O N N O T E S |
|
|
Industry: Plastics (Vacuum Molding) |
|
| Overview: Our client, an OEM, had purchased various components from Cross Automation and other sources. They were having difficulty integrating the components with each other after assembly on-site and required assistance in getting the equipment up and running. The customer had purchased eight Watlow Anafase temperature controllers and needed to communicate from those controllers to a Parker CTC P3 PowerStation HMI using Modbus RTU protocol. | |
| Discovery
By going on-site Cross Automation was able to discover the following information.
|
Challenges
|
System
Solutions
|
Customer
Benefits
By providing knowledgeable technical support at the OEM’s installation site, Cross Automation was able to solve the communications problem in a timely manner. The OEM was then able to complete the installation and get the end user’s equipment up and running on schedule. Cross Automation was able to solidify the relationship with the OEM by providing timely on-site assistance.
|
|
Return
to Application Notes Index |
|
Com Port 2 wiring diagram
P3 DB 9 RJ12 Jack on Anafase Temp Controller
1 TXD - 5 RX -
2 TXD + 2 RX +
3 RXD + 3 TX +
4 RXD - 4 TX -
5 Signal Ground 1 Common
6 DSR
7
RTS
8
CTS
9 RI
CPU 984
Protocol RTU
Baud 192000
Parity Even
Stop Bits 1
Com Port Com 2
Acquisition Rate Constant
Message Timeout 20
Wait for Writes? No
Write Buffer 10
Disabled
Start Offset 0
ASCII Terminator 0
ASCII Length 2